Charlotte Radon, Inc.

 

Remediation and Testing

 

This photo gallery contains pictures of a commercial Radon in Concrete Entire Building Remediation Project for a 5 Story 100 unit condominium building near dowtown Charlotte, NC that we did in 2009.  The concrete was X-rayed and the film was developed onsite to avoid cutting the post tension cables in the concrete.  Two fresh air ventilation systems were installed on the roof and ductwork was run throughout the entire building to ventilate the common areas as well as each individual condo unit.  This project was a great success and the radon level in ALL common areas and condo units was remediated to well below the USEPA action level of 4.0 pCi/L 

Radon Remediation Jobsite
5 Story Remediation Work Site
X-Ray Marked on Concrete For Cutting
Concrete Slab Cut-out
Crane Lifting Ventilation Equip to Roof
New Vertical Duct Running Between Floors
Fire Damper On Horizontal Duct Going To Corridor
Ductwork Crossing Breezeway
Stucco and Ceiling Repairs to Cover Duct
Technician Taking Care Not to Make a Mess
Access Hole For Ductwork From Corridor to Condo
New Branch Duct To Condo Unit
New 6 Inch Ventilation Grille in Condo
Testing and Balancing CFM Air Flow

980-230-2011